{"id":1528,"date":"2020-02-19T20:09:14","date_gmt":"2020-02-19T12:09:14","guid":{"rendered":"http:\/\/www.wmxray.com\/?p=1528"},"modified":"2023-11-27T10:21:46","modified_gmt":"2023-11-27T02:21:46","slug":"tube-voltage-and-tube-current-of-x-ray-tube","status":"publish","type":"post","link":"https:\/\/wmxray.com\/vi\/tube-voltage-and-tube-current-of-x-ray-tube\/","title":{"rendered":"Tube voltage and tube current of X-ray tube"},"content":{"rendered":"<h3 style=\"text-align: justify;\">When using <a href=\"https:\/\/wmxray.com\/vi\/product\/x-ray-inspection-system\/\">H\u1ec7 th\u1ed1ng ki\u1ec3m tra tia X<\/a>, we often adjust the tube voltage and tube current to make the imaging clearer. Increasing tube voltage can penetrate products with higher density and thickness; increasing tube current can make the image brighter. So, what is the principle of this phenomenon?<\/h3>\n<h3 style=\"text-align: justify;\">Tube voltage: Increasing tube voltage produces photon with higher frequencies and shorter wavelengths, that is, the energy of photons is higher, which allows photons to penetrate objects with higher density and thickness. Let me introduce a concept here, called X-ray hardness, which refers to the penetration ability of X-rays, which depends on the energy of photons, that is, the wavelength of X-rays, and has nothing to do with the number of photons. Therefore, the hardness of the X-ray is related to the tube voltage and has nothing to do with the tube current. The higher the tube voltage, the harder the X-rays are. The hardness of X-rays is usually expressed in kilovolts (kV) of tube voltage.<\/h3>\n<h3 style=\"text-align: justify;\">Before increasing tube voltage:<\/h3>\n<h3><img decoding=\"async\" class=\"size-full wp-image-1531 aligncenter\" src=\"https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage.jpg\" alt=\"\" width=\"1000\" height=\"1000\" srcset=\"https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage-66x66.jpg 66w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage-150x150.jpg 150w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage-200x200.jpg 200w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage-300x300.jpg 300w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage-400x400.jpg 400w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage-600x600.jpg 600w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage-768x768.jpg 768w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage-800x800.jpg 800w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/Before-raising-the-voltage.jpg 1000w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/h3>\n<h3>After increasing tube voltage:<\/h3>\n<h3><img decoding=\"async\" class=\"size-full wp-image-1530 aligncenter\" src=\"https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage.jpg\" alt=\"\" width=\"1280\" height=\"1280\" srcset=\"https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-66x66.jpg 66w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-150x150.jpg 150w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-200x200.jpg 200w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-300x300.jpg 300w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-400x400.jpg 400w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-600x600.jpg 600w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-768x768.jpg 768w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-800x800.jpg 800w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-1024x1024.jpg 1024w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage-1200x1200.jpg 1200w, https:\/\/wmxray.com\/wp-content\/uploads\/2020\/02\/After-raising-the-voltage.jpg 1280w\" sizes=\"(max-width: 1280px) 100vw, 1280px\" \/><\/h3>\n<h3 style=\"text-align: justify;\">Tube current: Increasing the tube current can increase the number of electrons that shoot the anode target, so that more photons penetrate the object and reach the flat panel detector. Usually we also use the milliamp number (mA) of the tube current to indirectly express the intensity of X-rays.<\/h3>\n<h3 style=\"text-align: justify;\">After increasing tube current:<\/h3>\n<div id=\"attachment_3156\" style=\"width: 910px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" aria-describedby=\"caption-attachment-3156\" class=\"size-full wp-image-3156\" src=\"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg\" alt=\"After raising the tube current\" width=\"900\" height=\"600\" srcset=\"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900-200x133.jpg 200w, https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900-300x200.jpg 300w, https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900-400x267.jpg 400w, https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900-600x400.jpg 600w, https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900-768x512.jpg 768w, https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900-800x533.jpg 800w, https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg 900w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><p id=\"caption-attachment-3156\" class=\"wp-caption-text\">After raising the tube current<\/p><\/div>","protected":false},"excerpt":{"rendered":"<p>When using X-ray inspection system, we often adjust the tube  [&#8230;]<\/p>","protected":false},"author":1,"featured_media":3156,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[12],"tags":[],"class_list":["post-1528","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Tube voltage and tube current of X-ray tube - Wellman X-Ray<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/wmxray.com\/vi\/tube-voltage-and-tube-current-of-x-ray-tube\/\" \/>\n<meta property=\"og:locale\" content=\"vi_VN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Tube voltage and tube current of X-ray tube - Wellman X-Ray\" \/>\n<meta property=\"og:description\" content=\"When using X-ray inspection system, we often adjust the tube [...]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/wmxray.com\/vi\/tube-voltage-and-tube-current-of-x-ray-tube\/\" \/>\n<meta property=\"og:site_name\" content=\"Wellman X-Ray\" \/>\n<meta property=\"article:published_time\" content=\"2020-02-19T12:09:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-27T02:21:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"wellman\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0110\u01b0\u1ee3c vi\u1ebft b\u1edfi\" \/>\n\t<meta name=\"twitter:data1\" content=\"wellman\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u01af\u1edbc t\u00ednh th\u1eddi gian \u0111\u1ecdc\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 ph\u00fat\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/\"},\"author\":{\"name\":\"wellman\",\"@id\":\"https:\/\/wmxray.com\/#\/schema\/person\/f394f706c1859b35ce4cae03c200b6f2\"},\"headline\":\"Tube voltage and tube current of X-ray tube\",\"datePublished\":\"2020-02-19T12:09:14+00:00\",\"dateModified\":\"2023-11-27T02:21:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/\"},\"wordCount\":243,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/wmxray.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"vi\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/\",\"url\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/\",\"name\":\"Tube voltage and tube current of X-ray tube - Wellman X-Ray\",\"isPartOf\":{\"@id\":\"https:\/\/wmxray.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg\",\"datePublished\":\"2020-02-19T12:09:14+00:00\",\"dateModified\":\"2023-11-27T02:21:46+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#breadcrumb\"},\"inLanguage\":\"vi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#primaryimage\",\"url\":\"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg\",\"contentUrl\":\"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg\",\"width\":900,\"height\":600,\"caption\":\"After raising the tube current\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/wmxray.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Tube voltage and tube current of X-ray tube\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/wmxray.com\/#website\",\"url\":\"https:\/\/wmxray.com\/\",\"name\":\"Wellman X-Ray\",\"description\":\"Professional X-Ray Solution Provider\",\"publisher\":{\"@id\":\"https:\/\/wmxray.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/wmxray.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"vi\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/wmxray.com\/#organization\",\"name\":\"Shenzhen Weiming Photoelectricity Co., Ltd\",\"url\":\"https:\/\/wmxray.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\/\/wmxray.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/wmxray.com\/wp-content\/uploads\/2020\/03\/Logo1.png\",\"contentUrl\":\"https:\/\/wmxray.com\/wp-content\/uploads\/2020\/03\/Logo1.png\",\"width\":278,\"height\":84,\"caption\":\"Shenzhen Weiming Photoelectricity Co., Ltd\"},\"image\":{\"@id\":\"https:\/\/wmxray.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/wmxray\",\"https:\/\/www.youtube.com\/channel\/UCCrB2m9YhMUdL_Bxuvz_GaA\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/wmxray.com\/#\/schema\/person\/f394f706c1859b35ce4cae03c200b6f2\",\"name\":\"wellman\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\/\/wmxray.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/wmxray.com\/wp-content\/litespeed\/avatar\/92b0ca4f31cf9fdbeb75d77a4255861c.jpg?ver=1776712786\",\"contentUrl\":\"https:\/\/wmxray.com\/wp-content\/litespeed\/avatar\/92b0ca4f31cf9fdbeb75d77a4255861c.jpg?ver=1776712786\",\"caption\":\"wellman\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Tube voltage and tube current of X-ray tube - Wellman X-Ray","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/wmxray.com\/vi\/tube-voltage-and-tube-current-of-x-ray-tube\/","og_locale":"vi_VN","og_type":"article","og_title":"Tube voltage and tube current of X-ray tube - Wellman X-Ray","og_description":"When using X-ray inspection system, we often adjust the tube [...]","og_url":"https:\/\/wmxray.com\/vi\/tube-voltage-and-tube-current-of-x-ray-tube\/","og_site_name":"Wellman X-Ray","article_published_time":"2020-02-19T12:09:14+00:00","article_modified_time":"2023-11-27T02:21:46+00:00","og_image":[{"width":900,"height":600,"url":"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg","type":"image\/jpeg"}],"author":"wellman","twitter_card":"summary_large_image","twitter_misc":{"\u0110\u01b0\u1ee3c vi\u1ebft b\u1edfi":"wellman","\u01af\u1edbc t\u00ednh th\u1eddi gian \u0111\u1ecdc":"2 ph\u00fat"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#article","isPartOf":{"@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/"},"author":{"name":"wellman","@id":"https:\/\/wmxray.com\/#\/schema\/person\/f394f706c1859b35ce4cae03c200b6f2"},"headline":"Tube voltage and tube current of X-ray tube","datePublished":"2020-02-19T12:09:14+00:00","dateModified":"2023-11-27T02:21:46+00:00","mainEntityOfPage":{"@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/"},"wordCount":243,"commentCount":0,"publisher":{"@id":"https:\/\/wmxray.com\/#organization"},"image":{"@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#primaryimage"},"thumbnailUrl":"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg","articleSection":["Blog"],"inLanguage":"vi","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/","url":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/","name":"Tube voltage and tube current of X-ray tube - Wellman X-Ray","isPartOf":{"@id":"https:\/\/wmxray.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#primaryimage"},"image":{"@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#primaryimage"},"thumbnailUrl":"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg","datePublished":"2020-02-19T12:09:14+00:00","dateModified":"2023-11-27T02:21:46+00:00","breadcrumb":{"@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#breadcrumb"},"inLanguage":"vi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/"]}]},{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#primaryimage","url":"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg","contentUrl":"https:\/\/wmxray.com\/wp-content\/uploads\/2023\/11\/IMG_202311038000_900x900.jpg","width":900,"height":600,"caption":"After raising the tube current"},{"@type":"BreadcrumbList","@id":"https:\/\/wmxray.com\/tube-voltage-and-tube-current-of-x-ray-tube\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/wmxray.com\/"},{"@type":"ListItem","position":2,"name":"Tube voltage and tube current of X-ray tube"}]},{"@type":"WebSite","@id":"https:\/\/wmxray.com\/#website","url":"https:\/\/wmxray.com\/","name":"Wellman X-Ray","description":"Professional X-Ray Solution Provider","publisher":{"@id":"https:\/\/wmxray.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/wmxray.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"vi"},{"@type":"Organization","@id":"https:\/\/wmxray.com\/#organization","name":"Shenzhen Weiming Photoelectricity Co., Ltd","url":"https:\/\/wmxray.com\/","logo":{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/wmxray.com\/#\/schema\/logo\/image\/","url":"https:\/\/wmxray.com\/wp-content\/uploads\/2020\/03\/Logo1.png","contentUrl":"https:\/\/wmxray.com\/wp-content\/uploads\/2020\/03\/Logo1.png","width":278,"height":84,"caption":"Shenzhen Weiming Photoelectricity Co., Ltd"},"image":{"@id":"https:\/\/wmxray.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/wmxray","https:\/\/www.youtube.com\/channel\/UCCrB2m9YhMUdL_Bxuvz_GaA"]},{"@type":"Person","@id":"https:\/\/wmxray.com\/#\/schema\/person\/f394f706c1859b35ce4cae03c200b6f2","name":"ng\u01b0\u1eddi \u0111\u00e0n \u00f4ng t\u1ed1t","image":{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/wmxray.com\/#\/schema\/person\/image\/","url":"https:\/\/wmxray.com\/wp-content\/litespeed\/avatar\/92b0ca4f31cf9fdbeb75d77a4255861c.jpg?ver=1776712786","contentUrl":"https:\/\/wmxray.com\/wp-content\/litespeed\/avatar\/92b0ca4f31cf9fdbeb75d77a4255861c.jpg?ver=1776712786","caption":"wellman"}}]}},"_links":{"self":[{"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/posts\/1528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/comments?post=1528"}],"version-history":[{"count":4,"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/posts\/1528\/revisions"}],"predecessor-version":[{"id":3336,"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/posts\/1528\/revisions\/3336"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/media\/3156"}],"wp:attachment":[{"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/media?parent=1528"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/categories?post=1528"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wmxray.com\/vi\/wp-json\/wp\/v2\/tags?post=1528"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}